What Is New In Psa Diagbox V7 V8 V9?auto Diagnostic Tool

  • PSA DiagBox V7.83 (8.19) Multilanguage DOWNLOAD.
  • Email to friends Share on Facebook - opens in a new window or tab Share on Twitter. PP2000 NEC Full Chip Lexia3 Diagbox W/ V7.83 921815C Diagnostic Tool for Citroen.

This article show the guide on how to install DiagBox v8.01 diagnostic software.This method provided by the cartechnology remember simple,big thanks to him selfless work.

Free Download PSA DiagBox V7.83 to install on a VMware machine and install on the native laptopVMware version:Option 1: PSA DiagBox V7.83 VMWARE English and Greek (by JimCar)Diagbo Return to site Free Download DiagBox V7.83 VMware and Native Install. Cheap Code Readers & Scan Tools, Buy Quality Automobiles & Motorcycles Directly from China Suppliers:Lexia 3 Lexia3 Diagbox V9.86 V7.83 PP2000 V48/V25 Full Chip Lexia3 FW921815C Diagnostic Tool For Citroen/Peugeot Lexia 3 Enjoy Free Shipping Worldwide! Limited Time Sale Easy Return.

Note: If using a Virtual Machine, ensure Virtualization is enabled in the physical laptop BIOS.

Preparation for Installing DiagBox 8.01 on Notebooks and VMWare Workstation
– Starting with any (32 bit) Windows (preferably XP or 7), install .NET 3.51 and Windows drivers or VMWare Tools (if on VMWare Workstation or Player).

What Is New In Psa Diagbox V7 V8 V9 Auto Diagnostic Tools

Preparation for Installing DiagBox 8.01 on VirtualBox
– Settings –> System: Motherboard, ensure APIC is OFF, use one processor and enable Virtualization. Allocate enough memory for VM.
– Having installed 32 bit Windows + VirtualBox Guest Additions + .NET 3.51, use the Powershell Command “Get-WMIObject win32_BIOS” or the “DMIdecode” tool to obtain BIOS information (not essential).
– Close VirtualBox and start an administrator’s CMD, navigate to “C:Program FilesOracleVirtualBox” and execute the following command (Replacing “Your VM” with your Virtual Machine’s name, and System Serial with your hardware’s or any code or text such as “CDN29326BH”):
C:Program FilesOracleVirtualBox>VBoxManage setextradata “Your VM” “VBoxInternal/Devices/pcbios/0/Config/DmiSystemSerial” “System Serial”

Installing DiagBox 8.01
1- Install DiagBox 7.01 and restart DiagBox to run update 7.02. Install update 7.xx-7.57 (this will create “C:AWRootdtwrcfgConfig.sys”).
2- Install “VC++ 2008 Redistributable Package”, a copy will be available in “C:teleassistancevisualCvcredist_x86.exe” after installing DiagBox.
3- Restart the computer and use “Kill_DiagBox_Tasks.bat” to stop related processes and rename “C:AWRoot” to “C:AWRoot7”
4- Run DiagBox 8.01 installation (it will uninstall v7.xx first) until it requests Activation. Close it (X) and run the tool “AWRoot_v7_Conf+Ativation_v8.exe” it will copy configuration from “C:AWRoot7..” and inject the necessary files.
5- Run DiagBox again, it should continue the installation successfully.

Done !,

Restart DiagBox 8.01 as Administrator to confirm all is well (don’t be concerned about the reported version and do not start Lexia or PP2000 yet). If you face an issue, run the activation tool again and/or review “Versions” below.

If DiagBox runs fine, ensure you keep a backup copy of the file “C:AWRootbinfiAPPDIAG.SYS” in a safe location.

Installing Updates
1- Download and install “DiagBox_updt_802.ISO” update.
2- Download and install subsequent v8.xx updates or Maitresox updates (from 7.66+).

Tool you need:

DiagBox Full v8.01 ISO:

What Is New In Psa Diagbox V7 V8 V9?auto Diagnostic Tool

AWRoot_v7_Conf+Ativation_v8.exe No password

DiagBox updates working with DiagBox V8.01 based on v7.xx profile, Extraction Password: Simple

DiagBox_updt_802_Simple.exe

DiagBox_updt_803-810_Simple.exe

What Is New In Psa Diagbox V7 V8 V9?auto Diagnostic Tool

DiagBox_updt_811-814_Simple.exe

DiagBox_updt_815-817_Simple.exe

For those who wish to stay with (ISO 639-1) standard:

DiagBox_updt_803-808_Simple.exe (7.72) Password: Simple #808

And those who wish to continue further:

DiagBox_updt_810_Simple.exe (7.74) No Password

Cache Contents Restorer No password

Kill_DiagBox_Tasks

Versions
DiagBox will run and display the (8.xx or 7.xx) version number listed in “AWRootbinfiversion.ini” file. However, Lexia or PP2000 will fail to operate with “version.ini” set to “08.xx” and “APPDIAG.SYS” will be corrupted and will need to be restored before DiagBox will work again.
So, for DiagBox, Lexia and PP2000 to operate, set the version to “7.xx” or “7.xxx” (07.81 or 07.817 can be set to indicate the true DiagBox 8 version).
[APPLICATION]
version=07.817

What Is New In Psa Diagbox V7 V8 V9 Auto Diagnostic Tool Download

It is possible to operate Lexia/PP2000 (after starting DiagBox with 8.xx) by starting DiagBox while having “version.ini” listing the 8.xx only (or first), then changing it to 7.xx or commenting the line “version=08.xx” and saving BEFORE starting LEXIA or PP2000 as shown below.
[APPLICATION]
;version=08.01
version=07.65

Updates
– DiagBox v7 and v8 install and run on all x86 (32bit) Windows including 10 TH1, TH2, RS1 and RS2.
– Entering a System Serial for the Virtual Machine (as described above) resolves the “psaAagent.exe” and the missing tabs issue on VirtualBox.
– If you get “Error 2” after restarting DiagBox, try commenting “version=8.xx” in “version.ini” before restarting DiagBox again.

P.S. DiagBox has been running on Firmware 4.3.4 since 7.66/8.02.

What Is New In Psa Diagbox V7 V8 V9 Auto Diagnostic Toolkit

Someone put the full installation process on the net, just edit “version.ini” as described above.

What Is New In Psa Diagbox V7 V8 V9 Auto Diagnostic Tool Kit

Readers who read this article also read:

Comments are closed.